EBERLE DESIGN LM222 INDUCTIVE LOOP DETECTOR It indicates vehicle presence with great accuracy and reliability,and also monitors the condition of the loop for diagnostic purposes. The LM222 Series meet or exceed all standards specified in NEMA publication TS 1-1989 part 15 (Inductive Loop Detectors) and Caltrans TSCES January 1989. Records previous fault information. If a problem self- heals, the LM222 will resume normal operation. The contents of the memory will be displayed on the Fault LED. This feature can be used to isolate the source of intermittent loop failures. Eliminates the confusion encountered with other detectors that use only one LED to display both faults and detection. The Fault LED displays the type of fault: Short, Open or 25% change of inductance. Each type of fault is indicated by a unique sequence of flashes allowing the user to diagnose Together, these features greatly reduce the incidence of crosstalk. Ensures reliable operation by continuously adjusting for changes in Allows users to fine tune the Loop Monitor Pulse: For counting and volume. For sites where loops may be occupied for extended (We do not proofread any ads submitted by members) |