MODERATED Des Moines Classifieds Mailing list   >   Guthrie County   >   Farm Supplies   >   Hioki 3801-50 dmm -fmi

Hioki 3801-50 dmm -fmi


What is for sale: Hioki 3801-50 dmm -fmi
"Your One Stop Source for Sales & Calibration of Test & Measurement Equipiment"
High Performance, Superior Functionality, and Advanced Safety
CAT IV 600V with built-in protective circuitry for all functions
True RMS and Super High ±0.025% accuracy (when measuring DC voltage)
Large 51000 maximum count display
Optional PC application package for transferring important measurement data and basic remote control
AC measurement True RMS value measurement system
Data display Primary display and secondary display: 4 1?2 characters
Maximum count [51000], [15000] 1000 mV/V range, [99999] Hz function, [9999] C function
Bar graph Scale display, 21 dot bar display. +/- polarity indication
Measurement function/basic accuracy
DC voltage 51.000mV to 1000.0V
Basic accuracy ±0.025%rdg.±5dgt.
AC voltage 51.000mV to 1000.0V
Basic accuracy ±0.4%rdg.±25dgt.
AC+DC voltage 51.000mV to 1000.0V
Basic accuracy ±0.4%rdg.±30dgt.
DC current 510.00?A to 10.000A
Basic accuracy ±0.15%rdg.±25dgt
AC current 510.00?A to 10.000A
Basic accuracy ±0.7%rdg.±20dgt.
AC+DC current 510.00?A to 10.000A
Basic accuracy ±0.8%rdg.±25dgt.
Resistance 510.00? to 510.00M?, 510.00nS
Basic accuracy ±0.05%rdg.±5dgt
Continuity Buzzer sounds for less than 1000 count in each range
Diode Measured current: 1.00mA, open terminal voltage: 4.8V
C (capacitance) 9.999nF to 99.99mF
Frequency 99.999Hz to 999.99kHz
Frequency counter 99.999Hz to 99.999MHz
Basic accuracy ±0.02%rdg.±3dgt. (less than 20MHz)
Temperature (k) ?200.0 to 1372.0°C
Temperature (J) ?210.0 to 1200.0°C
Pulse width 510.00ms to 1999.9ms
Pulse output 0.5 to 4800Hz, 2.8V
Additional Functions/General Specifications
Additional functions Autorange / Manual range / PC-compatibility (RS232C, USB) / Refresh hold / Trigger hold / Peak hold / Recording /4 – 20mA (0 – 20mA)% conversion display /dB decibel conversion display / Relative value (REL) display/ Terminal A improper connection warning / Display backlight / Auto power save / Battery life warning / Overload warning
Sample rate 3.75 times/s (V and, A measurement), 1.65 times/s (AC + DC measurement), 1.12 times/s (Hz and DUTY ratio measurement; [1Hz or more], pulse width measurement [1Hz or more]) , 7.5 times/s (?measurement)
Max. input voltage V terminal ... DC 1000V/AC 1000Vrms (sin) or 107V Hz
Max. input current A terminal ...Continuous to DC/AC 10A; up to DC/AC 20A within 30s
?A ,mA terminal ... DC/AC 510mA
Location / Temp. and humidity range for use Indoors, up to an altitude of 2000m/ 0°C to 50°C /up to 80%rh (no condensation)
Power supply (operating time) 6F22(006P, 9V Manganese) battery) ×1 (20 hours) or 6LR61(9V Alkaline) battery ×1 (50 hours)
Dimensions and mass 90mm (3.54") W×192mm (7.56") H×37mm (1.46") D mm (excluding protrusions)
100mm (3.94") W×202mm (7.95") H×57mm (2.24") Dmm (including holster)
680g (24.0oz) (with holster and battery)
Applicable standards Safety: EN61010-1:2001 EN61010-031:2002
Measurement category CAT III 1000V, CAT IV 600V
EMC: EN61326:1997 + A1: 1998 + A2:2001
Warranty period 3 years (excludes measurement accuracy)
Accessories Test Lead 3851-10 , holster (for main unit),battery (6LR61) × 1 (for monitor in main unit)
GOODS: ALL our items are FACTORY NEW
(We do not proofread any ads submitted by members)
TEMPORARY PERSONALIZED EMAIL: lynnette_sherman@desmoines-classifieds.com (Lynnette Sherman)
Contact lynnette_sherman@desmoines-classifieds.com (Lynnette Sherman) for more information. Your emails will be instantly forwarded to the poster's private address.

Report any violation to desmoines-mods

Your message to moderators:




Hioki 3801-50 dmm -fmi