The 695-200 is an exact replacement for the following Rheem/United Technologies part numbers:
United Technologies 1012-925A, 1012-925B, 1012-925C, Rheem 62-24268-01, 62-24268-02, 62-24268-03
• Field selectable fan delay (90, 120, 160, 180 seconds)
• High and low speed fan relay contacts
• Output terminal for air cleaner, humidifier, or fresh aircontrol (120VAC)
• Inducer pressure switch and thermal hi-limit failure detection
• Captive screw terminals for thermostat connections
• Microprocessor supervised for safe operation and accuracy
• Automatic resetting lockouts ensure safety but eliminatenuisance calls
• Electronic flame rectification sensing for safety and reliability
• Speed-up test mode aids quick and thorough system checkout
• Both sides conformal coated with acrylic for long life
• Compatible with all 24VAC thermostats including powerstealing and battery operated units
Input voltage range low ..............................18-30 VAC, 50/60 Hz
Input voltage range high ........................85 to 135 VAC, 50/60 Hz
Physical size (L x W x H) ....................................6.0" x 4.5" x 1.0"
Operating temperature range ................................-22°F to 149°F
Humidity range ......................10% to 95% Relative Humidity NC
Air circulation blower output ......FLA 13.8A, LRA 26A @ 120 VAC
Combustion inducer output..........FLA 2.2A, LRA 2.2A @ 120 VAC
Electronic air cleaner output ....1.0 A Resistive @ 120 VAC 60 Hz
Gas valve contact output ........................1.0 A @ 120 VAC, 60 Hz
HSI contact output ..................................5.0 A @ 120 VAC, 60 Hz
Thermostat terminations ..........................................C, R, W, G, Y
A green LED indicates system faults
Steady OFF: Board control fault or no power applied
1 Flash: Ignition failure (control in one-hour lockout)
2 Flashes: Pressure switch fault, fails open (switch is stuck open)
3 Flashes: Limit switch open (main or auxiliary)
4 Flashes: Pressure switch fault, fails closed (switch is stuck closed)
A yellow LED indicates flame status
Steady on: Normal flame is sensed
Flashes: As flame weakens, frequency of LED flashes increases
(We do not proofread any ads submitted by members)
TEMPORARY PERSONALIZED EMAIL: s_norris@desmoines-classifieds.com (Sharon Norris)
Contact s_norris@desmoines-classifieds.com (Sharon Norris) for more information. Your emails will be instantly forwarded to the poster's private address.

Report any violation to desmoines-mods

Your message to moderators:




Robertshaw 695-200 control board rheem / united tech